9.3 hBy our math: a 60,000 Btu/h gas furnace blower, high, 450 W

Updated Nov 25, 2026 · How we calculate

About 9.3 h for a 60,000 Btu/h gas furnace blower, high (450 W), by our math: 5,018 Wh × 0.85 ÷ (450 W + 11 W assumed for its own draw). Across the cases below: 4.2 h to 13.7 h.

Gas furnace hours on the TITAN 5000

  • 60,000 Btu/h gas furnace blower, low (NYSERDA)13.7 h†300 W
  • 60,000 Btu/h gas furnace blower, high (NYSERDA)9.3 h†450 W
  • 1/3 hp furnace fan (Honda chart) (Honda)4.2 h†1,000 W
The cases in a table, with the math
CaseWattsOn the TITAN 5000
60,000 Btu/h gas furnace blower, low (NYSERDA)300 W13.7 h †
60,000 Btu/h gas furnace blower, high (NYSERDA)450 W9.3 h †
1/3 hp furnace fan (Honda chart) (Honda)1,000 W4.2 h †

Wh × 0.85 ÷ (watts + 11 W own draw, our assumption: EcoFlow lists none). † Its output covers the start, but no surge rating is listed. Stock of the TITAN 5000 is unclear.

NYSERDA’s full-fire group averages, 4.9–7.1 W per 1,000 Btu/h of heat, come to about 290–430 W for a 60,000 Btu/h furnace’s blower; we use 300 and 450 W. Hours are nonstop; the blower cycles with the thermostat, so real hours are longer.

The TITAN 5000’s specs and price
SpecEcoFlow TITAN 5000
Battery5,018 Wh (maker spec)
Usable (× 0.85)4,265 Wh
Output / surge7,200 W / not listed
Own drawnot listed; 11 W assumed
Solar input4,000 W
Price$3,199 (Nov 22) at EcoFlow Stock unclear

Can the TITAN 5000 start it?

Honda lists 1,800 W to start a 1/3 hp furnace fan (Honda); EWEB’s chart gives about 2,100 W (EWEB). The TITAN 5000 has a 7,200 W output (no surge rating is listed). 60,000 Btu/h gas furnace blower, low: likely, though no surge rating is listed; check with EcoFlow; 60,000 Btu/h gas furnace blower, high: likely, though no surge rating is listed; check with EcoFlow; 1/3 hp furnace fan (Honda chart): likely, though no surge rating is listed; check with EcoFlow.

How much an hour takes

An hour of a 60,000 Btu/h gas furnace blower, high running nonstop uses about 450 Wh, about 11% of the TITAN 5000’s usable 4,265 Wh. At its 4,000 W solar input and our 75% assumption, strong sun puts about 3,000 Wh an hour back into the battery.

A furnace wired into the panel needs a transfer switch installed by a licensed electrician; never connect a backup to house wiring yourself.

Gas furnace on similar stations

StationCapacity60,000 Btu/h gas furnace blower, highPrice
Anker SOLIX S50005,024 Wh9.3 h$2,499.99
EcoFlow DELTA Pro Ultra6,144 Wh11.3 h$4,199 (Nov 22)
EcoFlow DELTA 3800 Gen43,763 Wh6.9 h$1,699
ALLPOWERS R40003,456 Wh6.4 h$1,499

Maker prices, Nov 23, 2026, unless dated. Checkout price applies.

More: EcoFlow TITAN 5000 specs and every runtime · Gas furnaces on every station · calculator for your own devices.

Quick answers

How long will the EcoFlow TITAN 5000 run a gas furnace’s blower?

About 9.3 h for a 60,000 Btu/h gas furnace blower, high (450 W), by our math: 5,018 Wh × 0.85 ÷ (450 W + 11 W assumed for its own draw).

Can the EcoFlow TITAN 5000 start a gas furnace’s blower?

Honda lists 1,800 W to start a 1/3 hp furnace fan; EWEB’s chart gives about 2,100 W. The TITAN 5000 has a 7,200 W output (no surge rating is listed). 60,000 Btu/h gas furnace blower, low: likely, though no surge rating is listed; check with EcoFlow; 60,000 Btu/h gas furnace blower, high: likely, though no surge rating is listed; check with EcoFlow; 1/3 hp furnace fan (Honda chart): likely, though no surge rating is listed; check with EcoFlow.

How long does the EcoFlow TITAN 5000 take to recharge with solar?

About 1.7 hours of strong sun from empty at its 4,000 W solar input, by our 75% assumption; clouds and winter sun add time.

“Paid link” = we earn a commission. Same math either way. See how we make money.