Solar in winter
How much power does a solar panel make in winter?
Much less than in summer, and much less lying flat. In December a 100 W panel lying flat makes about 1.9 kWh for the month in Seattle, WA and 7.7 kWh in Phoenix, AZ, by our scaling of NREL’s PVWatts model. Tilted south at about the latitude, the same panel makes 1.6–2.3 times as much. Below: 100, 200, 400 and 800 W kits in nine US cities, November to February.
kWh for your kit = PVWatts kWh for 1 kW × your panel watts ÷ 1,000
December: kWh for the month, and a day
| City and panel | 100 W | 200 W | 400 W | 800 W |
|---|---|---|---|---|
| Phoenix, AZFlat | 7.7 kWh0.25 kWh a day | 15.5 kWh0.50 kWh a day | 30.9 kWh1.00 kWh a day | 61.9 kWh2.00 kWh a day |
| Phoenix, AZTilted 33° | 13.4 kWh0.43 kWh a day | 26.9 kWh0.87 kWh a day | 53.7 kWh1.73 kWh a day | 107.5 kWh3.47 kWh a day |
| Dallas, TXFlat | 6.8 kWh0.22 kWh a day | 13.6 kWh0.44 kWh a day | 27.3 kWh0.88 kWh a day | 54.6 kWh1.76 kWh a day |
| Dallas, TXTilted 33° | 11.2 kWh0.36 kWh a day | 22.3 kWh0.72 kWh a day | 44.6 kWh1.44 kWh a day | 89.3 kWh2.88 kWh a day |
| Atlanta, GAFlat | 6.1 kWh0.20 kWh a day | 12.2 kWh0.39 kWh a day | 24.3 kWh0.78 kWh a day | 48.6 kWh1.57 kWh a day |
| Atlanta, GATilted 34° | 9.9 kWh0.32 kWh a day | 19.8 kWh0.64 kWh a day | 39.5 kWh1.27 kWh a day | 79.0 kWh2.55 kWh a day |
| Denver, COFlat | 5.7 kWh0.18 kWh a day | 11.5 kWh0.37 kWh a day | 22.9 kWh0.74 kWh a day | 45.8 kWh1.48 kWh a day |
| Denver, COTilted 40° | 11.9 kWh0.38 kWh a day | 23.8 kWh0.77 kWh a day | 47.6 kWh1.54 kWh a day | 95.2 kWh3.07 kWh a day |
| Asheville, NCFlat | 5.7 kWh0.18 kWh a day | 11.4 kWh0.37 kWh a day | 22.8 kWh0.74 kWh a day | 45.6 kWh1.47 kWh a day |
| Asheville, NCTilted 36° | 9.9 kWh0.32 kWh a day | 19.9 kWh0.64 kWh a day | 39.7 kWh1.28 kWh a day | 79.5 kWh2.56 kWh a day |
| Boston, MAFlat | 3.6 kWh0.12 kWh a day | 7.3 kWh0.24 kWh a day | 14.6 kWh0.47 kWh a day | 29.1 kWh0.94 kWh a day |
| Boston, MATilted 42° | 7.3 kWh0.24 kWh a day | 14.6 kWh0.47 kWh a day | 29.1 kWh0.94 kWh a day | 58.3 kWh1.88 kWh a day |
| Minneapolis, MNFlat | 3.3 kWh0.10 kWh a day | 6.5 kWh0.21 kWh a day | 13.0 kWh0.42 kWh a day | 26.0 kWh0.84 kWh a day |
| Minneapolis, MNTilted 45° | 7.5 kWh0.24 kWh a day | 15.1 kWh0.49 kWh a day | 30.1 kWh0.97 kWh a day | 60.3 kWh1.94 kWh a day |
| Bozeman, MTFlat | 2.5 kWh0.08 kWh a day | 5.0 kWh0.16 kWh a day | 10.0 kWh0.32 kWh a day | 20.0 kWh0.64 kWh a day |
| Bozeman, MTTilted 46° | 5.4 kWh0.17 kWh a day | 10.8 kWh0.35 kWh a day | 21.6 kWh0.70 kWh a day | 43.2 kWh1.39 kWh a day |
| Seattle, WAFlat | 1.9 kWh0.06 kWh a day | 3.8 kWh0.12 kWh a day | 7.6 kWh0.25 kWh a day | 15.2 kWh0.49 kWh a day |
| Seattle, WATilted 48° | 4.0 kWh0.13 kWh a day | 8.1 kWh0.26 kWh a day | 16.2 kWh0.52 kWh a day | 32.3 kWh1.04 kWh a day |
Our scaling of NREL’s PVWatts model’s results for 1 kW of panels facing south (100 W = 0.1 ×), read Nov 1–2, 2026: standard modules, fixed open rack, 14% system losses, typical-year weather (NSRDB PSM V3, tmy-2020). Flat = lying flat, as on an RV roof; tilted = facing south at about the city’s latitude. A day = the month ÷ 31, an average; cloudy days give less, clear days more.
January: kWh for the month
| City and panel | 100 W | 200 W | 400 W | 800 W |
|---|---|---|---|---|
| Phoenix, AZFlat | 8.2 kWh | 16.5 kWh | 33.0 kWh | 66.0 kWh |
| Phoenix, AZTilted 33° | 13.4 kWh | 26.7 kWh | 53.5 kWh | 106.9 kWh |
| Dallas, TXFlat | 7.2 kWh | 14.5 kWh | 28.9 kWh | 57.9 kWh |
| Dallas, TXTilted 33° | 11.2 kWh | 22.5 kWh | 45.0 kWh | 89.9 kWh |
| Atlanta, GAFlat | 6.7 kWh | 13.3 kWh | 26.7 kWh | 53.4 kWh |
| Atlanta, GATilted 34° | 10.5 kWh | 20.9 kWh | 41.8 kWh | 83.6 kWh |
| Denver, COFlat | 6.4 kWh | 12.9 kWh | 25.7 kWh | 51.5 kWh |
| Denver, COTilted 40° | 12.1 kWh | 24.2 kWh | 48.5 kWh | 96.9 kWh |
| Asheville, NCFlat | 6.6 kWh | 13.2 kWh | 26.4 kWh | 52.8 kWh |
| Asheville, NCTilted 36° | 10.7 kWh | 21.4 kWh | 42.7 kWh | 85.4 kWh |
| Boston, MAFlat | 5.0 kWh | 10.1 kWh | 20.1 kWh | 40.3 kWh |
| Boston, MATilted 42° | 10.1 kWh | 20.2 kWh | 40.3 kWh | 80.7 kWh |
| Minneapolis, MNFlat | 4.7 kWh | 9.3 kWh | 18.6 kWh | 37.2 kWh |
| Minneapolis, MNTilted 45° | 10.0 kWh | 19.9 kWh | 39.8 kWh | 79.6 kWh |
| Bozeman, MTFlat | 3.1 kWh | 6.2 kWh | 12.4 kWh | 24.9 kWh |
| Bozeman, MTTilted 46° | 6.5 kWh | 12.9 kWh | 25.8 kWh | 51.6 kWh |
| Seattle, WAFlat | 2.4 kWh | 4.8 kWh | 9.5 kWh | 19.0 kWh |
| Seattle, WATilted 48° | 4.9 kWh | 9.8 kWh | 19.6 kWh | 39.3 kWh |
Our scaling of NREL’s PVWatts model’s results for 1 kW of panels facing south (100 W = 0.1 ×), read Nov 1–2, 2026: standard modules, fixed open rack, 14% system losses, typical-year weather (NSRDB PSM V3, tmy-2020). Flat = lying flat, as on an RV roof; tilted = facing south at about the city’s latitude.
November to February, and the whole year, per 100 W
| City and panel | Nov | Dec | Jan | Feb | Year |
|---|---|---|---|---|---|
| Phoenix, AZFlat | 8.7 kWh | 7.7 kWh | 8.2 kWh | 9.4 kWh | 157 kWh |
| Phoenix, AZTilted 33° | 13.9 kWh | 13.4 kWh | 13.4 kWh | 13.3 kWh | 179 kWh |
| Dallas, TXFlat | 7.3 kWh | 6.8 kWh | 7.2 kWh | 7.7 kWh | 136 kWh |
| Dallas, TXTilted 33° | 10.8 kWh | 11.2 kWh | 11.2 kWh | 10.6 kWh | 151 kWh |
| Atlanta, GAFlat | 6.9 kWh | 6.1 kWh | 6.7 kWh | 7.3 kWh | 129 kWh |
| Atlanta, GATilted 34° | 10.5 kWh | 9.9 kWh | 10.5 kWh | 9.8 kWh | 143 kWh |
| Denver, COFlat | 7.1 kWh | 5.7 kWh | 6.4 kWh | 8.2 kWh | 138 kWh |
| Denver, COTilted 40° | 13.0 kWh | 11.9 kWh | 12.1 kWh | 12.7 kWh | 163 kWh |
| Asheville, NCFlat | 6.7 kWh | 5.7 kWh | 6.6 kWh | 8.0 kWh | 127 kWh |
| Asheville, NCTilted 36° | 10.7 kWh | 9.9 kWh | 10.7 kWh | 11.2 kWh | 143 kWh |
| Boston, MAFlat | 4.8 kWh | 3.6 kWh | 5.0 kWh | 6.6 kWh | 114 kWh |
| Boston, MATilted 42° | 8.5 kWh | 7.3 kWh | 10.1 kWh | 10.5 kWh | 133 kWh |
| Minneapolis, MNFlat | 4.2 kWh | 3.3 kWh | 4.7 kWh | 6.4 kWh | 113 kWh |
| Minneapolis, MNTilted 45° | 8.1 kWh | 7.5 kWh | 10.0 kWh | 11.0 kWh | 136 kWh |
| Bozeman, MTFlat | 3.5 kWh | 2.5 kWh | 3.1 kWh | 4.7 kWh | 110 kWh |
| Bozeman, MTTilted 46° | 6.7 kWh | 5.4 kWh | 6.5 kWh | 7.7 kWh | 127 kWh |
| Seattle, WAFlat | 2.5 kWh | 1.9 kWh | 2.4 kWh | 4.0 kWh | 96 kWh |
| Seattle, WATilted 48° | 4.6 kWh | 4.0 kWh | 4.9 kWh | 6.4 kWh | 107 kWh |
Our scaling of NREL’s PVWatts model’s results for 1 kW of panels facing south (100 W = 0.1 ×), read Nov 1–2, 2026: standard modules, fixed open rack, 14% system losses, typical-year weather (NSRDB PSM V3, tmy-2020). Flat = lying flat, as on an RV roof; tilted = facing south at about the city’s latitude. For 200 W multiply by 2, for 400 W by 4, for 800 W by 8.
Winter is the low point of the year. Lying flat in Seattle, WA, a panel makes about 13% as much in December as in July, its best month in these figures.
What a December day runs
A power station loses some energy turning its battery into 120 V AC. We count 0.85 of the solar energy as reaching your devices, the same factor we use for the battery (how we calculate). With that:
- Fridge. An average US fridge uses about 1,690 Wh a day: 70.4 W averaged, from 617 kWh a year (EIA). Covering that on an average December day takes about 460–1,520 W of panels tilted south, or 800–3,240 W lying flat, in these nine cities.
- CPAP. A ResMed AirSense 10 with the humidifier uses 22 W (ResMed): 176 Wh for an eight-hour night, so 207 Wh of solar. A 200 W kit makes that on an average December day in seven of the nine cities lying flat and nine tilted.
- Wi‑Fi. A modem and router at about 11 W (NRDC) use 264 Wh a day, so 311 Wh of solar: a 200 W kit makes that in five of the nine cities lying flat and eight tilted.
These three leave out the station’s own draw while it is on (the maker’s figure, or 11 W where it lists none). At 11 W that is about 264 Wh a day if the station stays on, so it matters most for small loads: the Wi‑Fi example then takes about 621 Wh of solar a day. The calculator counts it.
The calculator’s solar option assumes 4 sun hours a day at 75% of the panels’ rating, about 3.0 kWh a day per 1,000 W, all year. That’s more than every flat December figure here (0.6–2.5 kWh a day per 1,000 W), so for winter use this page’s numbers.
The station also has to hold the day’s solar for the night, and a fully charged station can’t take more. For your own list of devices, use the calculator; its solar option counts the same 0.85 factor.
| City and panel | 400 W kit: Wh a day for your devices | Share of an average fridge’s day | Panels for a whole fridge day |
|---|---|---|---|
| Phoenix, AZFlat | 848 Wh | 50% | 800 W |
| Phoenix, AZTilted 33° | 1,473 Wh | 87% | 460 W |
| Dallas, TXFlat | 748 Wh | 44% | 900 W |
| Dallas, TXTilted 33° | 1,224 Wh | 72% | 550 W |
| Atlanta, GAFlat | 666 Wh | 39% | 1,010 W |
| Atlanta, GATilted 34° | 1,083 Wh | 64% | 620 W |
| Denver, COFlat | 628 Wh | 37% | 1,080 W |
| Denver, COTilted 40° | 1,305 Wh | 77% | 520 W |
| Asheville, NCFlat | 626 Wh | 37% | 1,080 W |
| Asheville, NCTilted 36° | 1,090 Wh | 64% | 620 W |
| Boston, MAFlat | 400 Wh | 24% | 1,690 W |
| Boston, MATilted 42° | 799 Wh | 47% | 850 W |
| Minneapolis, MNFlat | 356 Wh | 21% | 1,900 W |
| Minneapolis, MNTilted 45° | 827 Wh | 49% | 820 W |
| Bozeman, MTFlat | 274 Wh | 16% | 2,470 W |
| Bozeman, MTTilted 46° | 592 Wh | 35% | 1,140 W |
| Seattle, WAFlat | 209 Wh | 12% | 3,240 W |
| Seattle, WATilted 48° | 443 Wh | 26% | 1,520 W |
Our math: the average December day from PVWatts (scaled, ÷ 31) × 0.85. PVWatts’ monthly output is already AC, after its default inverter efficiency (96%, with a 1.2 DC-to-AC ratio, per the v8 docs), so our 0.85 on top is conservative. Average US fridge 1,690 Wh a day (EIA). Panels for a whole fridge day = 1,690 Wh ÷ 0.85 ÷ the kit’s kWh a day per watt, before the station’s own draw.
Why your kit may make less
- The model’s setup. PVWatts comes from NREL, now the National Laboratory of the Rockies (DOE). We set it to a fixed array facing due south, on an open rack, with standard modules and 14% system losses, in typical-year weather (TMY), not any one real year (PVWatts API v8). It assumes no shade beyond those losses. A real December can be cloudier than the typical one.
- Snow, shade and low sun. These figures are for a panel kept clear of snow and shade, which is our assumption. Snow lying on a panel, shade from trees, buildings or hills when the winter sun is low, or a panel not facing south all cut output, and a portable panel in a real winter can get any of them.
- Panels and charge controllers. PVWatts models panels feeding an inverter that makes AC, not a folding panel feeding a power station. Rated watts are lab figures, and a portable panel can differ from the model’s standard module. The station’s own solar input limits what it takes: the stations we list accept 200–5,600 W, within voltage and current limits, so a kit bigger than the station’s input can give less than the table when the sun is strong. Which panels fit which stations.
- Our 0.85 factor. It’s our figure for the energy lost turning battery power into 120 V AC, the same as everywhere on this site. USB‑C and 12 V outputs lose less.
- Cold. Of the 23 stations we list, 20 are rated to charge only at 32°F or above; two can charge below freezing; one lists no charging temperature. A station left in a freezing car or shed may make no use of the sun until it warms up. Power stations in cold weather.
- Our scaling. We ran PVWatts for 1 kW of panels and scaled it in proportion: 100 W = 0.1 ×, 800 W = 0.8 ×. PVWatts used weather for a grid point 0.7–2.2 km from each city’s coordinates.
How long a kit takes to refill a station in strong sun: solar recharge time. Kits from one maker: solar generator kits. You can run the same model for your own address on PVWatts.
Quick answers
How much power does a 100 W solar panel make in winter?
In December, about 1.9 kWh for the month lying flat in Seattle, WA and 7.7 kWh in Phoenix, AZ, or 61–250 Wh a day, by our scaling of NREL’s PVWatts model for nine US cities. Tilted south at about the latitude, it’s 4.0–13.4 kWh.
How much does a 400 W solar kit make in December?
About 7.6–30.9 kWh for the month lying flat across the nine cities here, 16.2–53.7 kWh tilted toward the south at about the latitude. On an average December day that’s 0.25–1.00 kWh flat and 0.52–1.73 kWh tilted.
Can a solar panel kit run a fridge in winter?
An average US fridge uses about 1,690 Wh a day (70.4 W, EIA). To cover that on an average December day, after our 0.85 factor, takes about 460–1,520 W of panels tilted south in the nine cities here, and 800–3,240 W lying flat, by our math, before the station’s own draw. Cloudy days give less, and the station needs a battery big enough to carry the fridge through the night.
Does tilting a solar panel help in winter?
A lot, in these figures: a panel facing south at about the latitude makes 1.6–2.3 times as much in December as one lying flat, from 1.6× in Atlanta, GA to 2.3× in Minneapolis, MN.
Will a power station charge from solar below freezing?
Not most of them, by the makers’ specs. Of the 23 stations we list, 20 are rated to charge only at 32°F or above; two can charge below freezing; one lists no charging temperature. The panels can make power, but the station won’t store it until it’s within its charging range.
In stock at the last check
Cheapest in stock · Lowest price per Wh in stock · Largest in stock
EcoFlow DELTA 2 Max
2,048 Wh, 2,400 W output. $0.50 per Wh.
$1,029 at EcoFlow, Nov 23
Maker prices, Nov 23, 2026, unless dated. Checkout price applies. Stock is what each maker’s US store showed then; confirm it at the store. Compare all 23 stations or find one for your devices.
“Paid link” = we earn a commission. Same math either way. See how we make money.